ASM Lab

Introduction

ASM Lab 1.45

ASM Lab is a mine ventilation program for designing, checking and simulating the ventilation of underground mines. You draw the mine's airways in 3D, or import them from a drawing or another program, place the fans, regulators, walls and doors, and ASM Lab calculates the airflow in every airway. It then goes further than airflow: the temperature and humidity of the air, the gases and dust it carries, and how a fire would spread smoke and heat through the mine.

Version 1.45 is the release this manual describes. It brings together everything built into ASM Lab so far: the network solver, the thermal solver, the fire module, the duct module, scripting, the ASM Assistant, the human (worker) module and the engineering calculators.

What ASM Lab simulates

SimulationWhat you get
AirflowThe flow (m³/s), velocity, pressure drop and air power of every airway, the pressure at every junction, and the operating point of every fan.
Temperature and humidityDry- and wet-bulb temperature, relative humidity, moisture and heat content along every airway, with heat from the rock, machines, people, blasting and auto-compression, and cooling by bulk air coolers.
GasesCarbon monoxide, carbon dioxide, methane and other gases released in an airway, followed through the network against their exposure limits.
DustRespirable and inhalable dust and diesel particulate matter carried with the air.
FireHeat and smoke carried through the network over time: temperature, oxygen, CO and CO₂ at every place, airflow changes and reversals caused by the fire, and when the smoke first reaches each place.
PeopleHeat stress for workers at a stated work rate and clothing, and the human module for stope layouts and evacuation.

Mining methods

ASM Lab models any mine whose ventilation can be described as a network of airways joined at junctions, so it is not limited to one mining method.

What ASM Lab is for

How ASM Lab works

ASM Lab describes the mine as a network. Each excavation the air passes through (a drive, a shaft, a raise, a stope) is an airway, drawn as its centre line in 3D with a cross-section. Airways meet at nodes: a node where airways meet is a junction, and a node at the end of an airway is an end, open to the surface or closed.

Each airway has a resistance to airflow, worked out from its length, its cross-section and the roughness of its walls (the Atkinson friction factor k), plus any shock losses at bends and changes of section. Devices placed on airways add or remove pressure: fans push the air, regulators and walls restrict it. Boundaries tell ASM Lab where air enters and leaves the mine.

When you solve, ASM Lab finds the airflow in every airway so that the air entering each junction equals the air leaving it, and the pressure drops around every loop add up to what the fans supply. The thermal solver then follows the air through the network and works out how its temperature and moisture change in each airway.

Screenshot 1: A small network in the 3D view with labels: an airway, a junction node, an end node, a fan, a regulator, an intake and an exhaust.
Figure 1: A small network in the 3D view with labels: an airway, a junction node, an end node, a fan, a regulator, an intake and an exhaust

Airway shapes

ShapeTypical use
RectangularDevelopment drives and crosscuts cut to a square profile.
Horseshoe and D-shapeDrives with an arched roof.
CircularShafts, raise-bored raises and ducts.
Elliptical and egg-shapedShafts and airways with a non-circular rounded section.
TrapezoidalWider at the floor than the roof, as in some drives and coal roadways.
CustomAny section you draw or import; its area and perimeter set the resistance.

Airway kinds

Every airway has a kind, which sets its default section and colour and lets you find and report airways by what they are: drive, shaft, station, ramp, raise, stope, drawpoint, ore pass and chamber.

Devices and boundaries

ItemWhat it does
Fan (main, booster, auxiliary)Adds pressure to its airway along a fan curve (pressure, efficiency and power against flow), at a set pressure, or holding a set flow.
RegulatorRestricts an airway to hold a set flow, a set pressure drop, a set resistance or a set opening.
Wall, door, seal, brattice, louvreCloses or restricts an airway; standard types with their resistances are included (brick, concrete, shotcrete, good and poor seals, brattice, louvre, rope choke and others).
CoolerCools and dries the air in an airway to a set outlet state or duty.
Refuge bayMarks a refuge chamber on an airway, for fire and escape studies.
Intake and exhaustBoundaries where air enters or leaves the mine at a given pressure and temperature.

How it calculates

The equations, their sources and the checks against hand calculations and other programs are in the Solver guide.

Ways to build a model

Document conventions

Typographical conventions

FormatMeaning
BoldA button, menu, tab, field or other part of the screen, a file name, or text you type. For example: click Solve.
ItalicEmphasis, or a term explained where it first appears.
<angle brackets>Text that changes with each use, such as <project name>. Do not type the brackets.

Keyboard conventions

Key combinationMeaning
key+keyHold down the first key and press the second. For example, Ctrl+S means hold Ctrl and press S.
A single keyPress it with the 3D view active. For example, A starts drawing a tunnel.

File > Save As means click the File menu, then Save As. Home > Create > Draw tunnel means the Home tab of the ribbon, the Create group, the Draw tunnel button.

Mouse conventions

ActionDescription
ClickPress and release the left mouse button.
Right-clickPress and release the right mouse button. While drawing, right-click finishes the airway chain.
Double-clickClick the left button twice quickly.
Left-drag in the 3D viewRotates the view.
Right-drag in the 3D viewPans the view.
WheelZooms the view in and out.